Entry 01 Signs & causes
Six ways a cooktop goes quiet
Write down which of these matches what happened, and what was on the glass at that moment. That detail narrows the cause faster than anything else said on the phone.
-
Observed
The breaker in the panel flips the moment two or three zones run on high together
Probable cause
The circuit is running near its limit, or the breaker itself has weakened after years of heat; the cooktop may be perfectly healthy
Repair page -
Observed
The breaker drops the instant the power key is touched, with the glass still empty
Probable cause
A short inside the unit, often a failed power board or a damaged internal lead, and a strong reason to leave the unit off until it has been tested
-
Observed
The glass goes dark mid-cook, yet the panel shows the breaker still closed
Probable cause
Overheat protection kicking in: the fan under the glass has failed, or the vents under the unit blocked by whatever is stored in the drawer below
-
Observed
One zone keeps powering down while the others behave
Probable cause
Pan detection losing the pot (a warped or non-magnetic base) or a weak coil and its driver on that zone
-
Observed
Shut-offs happen mostly on humid, foggy days
Probable cause
Moisture settling on the touch controls or around connections in a cabinet that never dries out completely
-
Observed
Lights flicker or the dishwasher stops when the cooktop starts heating
Probable cause
The cooktop sharing a circuit or a crowded panel with other loads, a wiring question more than an appliance one