Entry 01 Signs & causes
When all the burners run small at once
One weak burner usually points at that burner. Every burner weak together is a different pattern, and the specifics narrow it down quickly. The full catalog of range faults lives on the main Wolf range page; this list sticks to the low-flame problem.
-
Observed
Every flame is low and soft, even with the knobs turned all the way up
Probable cause
Not enough gas reaching the range: a shutoff left partly closed after inspection, a pinched flexible connector, or house piping too narrow for the new load
-
Observed
The flames shrink whenever the water heater, furnace or fireplace fires up
Probable cause
A shared supply that cannot cover everything now running on it, typical when a remodel added gas appliances to the original service
-
Observed
Tiny, stable flames that take ages to bring a pot to a boil
Probable cause
A range set up for propane while the house runs natural gas, with orifices or the appliance regulator never converted
Repair page -
Observed
Tall, lazy, yellow-tipped flames on every burner
Probable cause
The opposite mismatch or a regulator fault; stop cooking on it until someone has looked
-
Observed
Weak top burners and, on an all-gas model, an oven that crawls toward its set heat
Probable cause
One feed serves the whole appliance, so a supply shortfall shows up everywhere at once
-
Observed
Only one or two burners are weak while the rest burn normally
Probable cause
A burner-level issue such as an off-center cap, ports packed with residue or a sticky valve, which is squarely a range repair
Repair page
Gas smell: get out first
Gas smell: get out first
A whiff of gas changes the order of everything. Nobody flips a switch, turns a knob or fiddles with the valve; people simply walk out, kids and pets included, and keep going until they are well clear of the house. Then phone 911 or the gas utility's emergency line. The range waits until the utility clears the house.
Logged reply2 / 3
Why are the burners weak on my new Wolf range?
When all the burners on a new range run low together, suspect the supply first: a half-open shutoff, a kinked connector, piping sized for the old kitchen, or a unit still set up for propane. One lone weak burner, by contrast, usually means a cap, port or valve problem inside the range.